Technical Parameters
Technical Parameters
Laser Type | 355nm UV laser source |
Working Field | 100*100mm~300*300mm |
Input Beam Size | ≤6.5mm |
X&Y Axes Mirrors Aperture Size | 10mm |
Precision and Error | |
Linearity | 99.90% |
Repeatability (RMS) | <8μRad |
Gain Error | <5mRad |
Zero Offset | <5mRad |
Long-term Drift Over 8 Hours | <0.5mRad |
Scale Drift | <40PPM/℃ |
Zero Drift | <15μRad/℃ |
Power and Signal | |
Input Voltage | ±24VDC |
Rated Current | 4A |
Interface Signal | Digital: XY2-100 |
Machinery Scan Angle | ±12.5° |
Working Current, Temperature, Dimension | |
Working Temperature | 0℃~45℃ |
Storage Temperature | -10℃~60℃ |
Galvanometer Scanner Dimension | 310X110X116mm (LxWxH) |
Galvanometer Scanner Weight | ≈4.23Kg |
Examples of Field Size, Focal Length, and Spot Size Configurations | |||
Field Size | 100×100mm | 200×200mm | 300×300mm |
Focal length | 160mm | 215mm | 315mm |
Spot Size | 0.01mm | 0.015mm | 0.022mm |
Depth | 40mm | 80mm | 80mm |